General Description
The bulkhead mounted hand pump is used when the hand
pump can’t be mounted directly on the actuator i.e. extra pipe
and block installation is required. Due to for example limited
space near the valves or a submerged valve that can’t be ac-
cessed at all. The bulkhead mounted hand pump exists in a
standard version and VPI version.
The bulkhead mounted hand pump requires always a tank. The
tank size and tank type determines according to hand pump
functionality. Please note that a bulkhead mounted LPU must
be mounted with the tank upwards, but a LPU mounted directly
on the actuator can be mounted with an arbitrary tank position.
Note!
The very large actuators are not recommendable to be oper-
ated by standard handpump - ask for directions.
Hand pump type Range
HP-D-B-1 BRC 125 - 8000 & KC 65 - 400
HP-D-B-VPI-V-1 * BRC 125 - 8000 & KC 65 - 400
HP-S-B-1 BRCF 125 - 2000 & KF 65 - 200
HP-S-B-4 BRCF 4000
HP-S-B-VPI-V-1* BRCF 125 - 2000 & KF 65 - 250
HP-S-B-VPI-4* BRCF 4000
Application
*)Please note that oil volume must be taken into consideration to determine the correct VPI gear ratio.
Damcos
™
Hand Pump - Bulkhead Mounted
January 2012
3
Bulkhead Mounted Handpump for HP-D-B-1 and HP-S-B-1
HP-D-B-1 HP-S-B-1
Installation Requirements for HP-D-B-1 and HP-S-B-1/4
− Length between actuators and hand pump: La < 30 m.
− Handpump between main supply source SPU/Valve cabinet and actuator, see hydraulic diagram.
Damcos
™
Hand Pump - Bulkhead Mounted
January 2012
4
Hydraulic Diagram for HP-D-B-1
8. Remote connection line A (CLOSE)
9. Stop valve
10. Direction valve
11. Hand pump handle
12. Tank
13. Control block
14. Bulkhead plate
18. Bulkhead block for hand pump
1. Double line actuator
2. Bypass valve
3. Double pilot operated check valve
4. Check valve
5. Throttle valve
6. Filter
7. Remote connection line B (OPEN)
Dimensions for HP-D-B-1
Damcos
™
Hand Pump - Bulkhead Mounted
January 2012
5
Hydraulic Diagram for HP-S-B-1/4
1. Single line actuator
2. Bypass valve
3a. Stop valve (2)
5a. Stop valve (1)
6. Filter
7. Remote connection line B (OPEN)
11. Hand pump handle
12. Tank
13. Control Block
14. Bulkhead plate
18. Bulkhead block for hand pump
Dimensions for HP-S-B-1/4
Damcos
™
Hand Pump - Bulkhead Mounted
January 2012
6
Bulkhead Mounted Handpump with VPI
HP-D-B-VPI-V-1 HP-S-B-VPI-V-1
Installation Requirements for HP-D-B-VPI-1 and
HP-S-B-VPI-V-1/4
− Length between actuators and hand pump: La < 30 m.
− Handpump between main supply source SPU/Valve cabinet and actuator, see hydraulic diagram.
Damcos
™
Hand Pump - Bulkhead Mounted
January 2012
7
Hydraulic Diagram for HP-S-B-VPI-V-1
9. Stop valve
10. Direction valve
11. Hand pump handle
12. Tank
13. Control block
14. Bulkhead plate
18a1 Bulkhead block with VPI for hand pump
1. Double line actuator
2. Bypass valve
3. Double pilot operated check valve
4. Relief valve
5. Throttle valve
6. Filter
7. Remote connection line B (OPEN)
8. Remote connection line A (CLOSE)
Dimensions for HP-S-B-VPI-V-1
Damcos
™
Hand Pump - Bulkhead Mounted
January 2012
8
Hydraulic Diagram for HP-S-B-VPI-V-1/4
11. Hand pump handle
12. Tank
13. Actuator Block
14. Bulkhead plate
18a. Bulkhead block with VPI for hand
pump
1. Single line actuator
2. Bypass valve
3a. Stop valve (2)
5a. Stop valve (1)
6. Filter
7. Remote connection line B (OPEN)
Dimensions for HP-S-B-VPI-V-1/4
Damcos
™
Hand Pump - Bulkhead Mounted
January 2012
9
Bulkhead Mounted Handpump for LPU
HP-D-B-50 HP-S-B-50
Installation Requirements for HP-D-B-50 and HP-S-B-50
− Length between actuators and hand pump:
Ll + La < 30 m.
− Main supply source (LPU) between hand pump and actuator
− Closed tank type must be used together with LPU.
− An additional pressurized LPU tank must occasionally be
added dependent on actuator size and distance between
hand pump and actuator.
− LPU connection block must be used:
− To de-air pipes between hand pump and LPU
− For easier troubleshooting and maintenance
LPU connection block
Product Data Sheet
January 2012
TM
Damcos
™
Hand Pump - Bulkhead Mounted
SD 6702-2E06
©2012 Emerson Process Management. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos
®
and the
Damcos logotype are registered trademarks of Damcos A/S.
All rights reserved.
The contents of this publication are presented for information purposes only, and while effort has
been made to ensure their accuracy, they are not to be construed as warranties or guarantees,
expressed or implied, regarding the products or services described herein or their use or
applicability. Standard Terms and Conditions of Sale can be issued by contacting Damcos A/S. We
reserve the right to modify or improve the designs and specifications of our products at any time
without notice.
Emerson Process Management
Damcos A/S
Aaderupvej 41
DK-4700 Naestved
T +45 5578 7200
F +45 5578 7272
www.EmersonProcesss.com/mtm